Grand Meyer® HW500

Programmable temperature controller with an updated design for underfloor heating control. Possibility of programmable and manual control. Possibility to set a weekly period of 5+2/6+1/7 days. Memory settings when power off. Built-in temperature sensor and external NTC sensor 3 m long. Maximum load up to 16A. HW500 has 2 body colors: white and ivory. The temperature controller controls the operation of the underfloor heating according to the readings of the floor temperature sensor (included in the delivery set) or according to the readings of the ambient air temperature build-in sensor, or a combination of both sensors. The temperature controller HW-500 is designed for hidden (recessed) mounting in the socket of the mounting box.

SPECIFICATIONS
Power supply
~230V (-15%, +10%), 50Hz
Switched current/power
16 A / 3.6 kW
Power consumed by the regulator with the load switched off, no more
2 W
Regulatory principle
On / Off
Output relay
trailing
Operating temperature
from -5⁰С to +50⁰С
Temperature sensors
Built-in and external
Temperature control limits
from +5⁰С to +95⁰С (factory from +5⁰С to +35⁰С)
Hysteresis (configurable)
from 0.5⁰С to 10⁰С
Remote sensor resistance
10kOhm at +25⁰С
Remote sensor connecting cable length
3m
Frost protection function
Yes
Programming mode
5+2/6+1/7 days
Body material
Self-extinguishing PVC
Degree of protection
IP20
Assembly dimensions
90 (H) x 86 (W) x 43 (D) mm
Body color
White or ivory
Weight
142 g
Warranty
1 Year
Certified
СЕ, ЕАС

Simplicity and comfort

The temperature controller has programmable and manual control functions.

Button control

Датчики температуры​

Терморегулятор автоматически поддерживает заданную температуру обогреваемой поверхности по показаниям датчика температуры пола (входит в комплект поставки) или по показаниям датчика температуры окружающего воздуха (встроен в регулятор), или в комбинации обоих датчиков.

Heating cable

Sensor

External terminal contact

Mains earth conductor

Temperature sensors

The temperature controller automatically maintains the set temperature of the heated surface according to the readings of the floor temperature sensor (included in the delivery set) or according to the readings of the ambient air build-in temperature sensor, or a combination of both sensors.

Location of the external temperature sensor

When using a built-in sensor or a combination of both sensors, the temperature controller must be installed on a wall with free air circulation around it. In addition, it should be placed where there is no exposure to another heat source (sun, radiators, etc.), from doors or windows, or exposure to ambient temperature.

Sensor