OHC30

Twin-core 30 w/m resistive heating cable extended power and protection for outdoor use. Can be used for parking areas, roadways, sidewalks, external stairs, loading ramps,
bridges, soil surfaces, roofs and gutters to prevent icing. Cable can be installed into cement-sand mortar, concrete, sand, soil or on open surfaces such as roofs and gutters.

SPECIFICATIONS OF THE HEATING CABLE
Cable type
twin-core screened
Power supply
~230V
Linear power at rated voltage
30 W/m
Maximum operating temperature
+90⁰С
Minimal installation temperature
-30⁰С
Minimum bend radius
150 mm
Cable outer diameter
6.5 mm
Installation wire feeding the heating cable
3.0m, (H05RN-F)
Color of connected wires
brown - phase (L), blue - zero (N), yellow-green - "ground" (PE)
Length tolerances
±0.5%
Mechanical strength according to IEC 60800
class M2

Heating cable design

1.Heating element: two heating conductors made of CuNi, CoCr, NiCr alloys.
2. Fluoroplastic insulation (FEP).
3. Internal protective shield made of cross-linked polyethylene (XLPE).
4. Drainage conductor.
5, Aluminum foil screen.
6. Outer shield: Irradiated PVC with UV protection.

Technical characteristics of Loose Heating Cable Grand Meyer OHC30

Cable article
HEATING PART LENGTH, M
POWER, W
CURRENT, A
RESISTANCE, OhM
OHC30-10
10
300
1.4
167.51 ... 193.96
OHC30-20
20
600
2.7
83.76 ... 96.99
OHC30-30
30
900
4.1
55,84 ... 64.66
OHC30-40
40
1200
5.5
41.88 ... 48.49
OHC30-50
50
1500
6.9
33.50 ... 38.79
OHC30-60
60
1800
8.2
27.90 ... 32.31
OHC30-70
70
2100
9.6
23.93 ... 27.71
OHC30-90
90
2700
12.40
18.61 ... 21.55

Installation of the Loose Heating Cable Grand Meyer THC20

  1. Base layer – compacted soil mixed with crushed stone 40-60 mm, with compaction coefficient Kcom=0.95. Recommended layer from 100 to 300 mm.
  2. Polyurethane Concrete. Min 9 mm. 
  3.  Thermal insulation – extruded polystyrene foam boards with density at least 45 kg/m3. Min. thickness 100 mm.
  4.  Reinforced concrete or reinforced cement-sand mortar Min. 30 mm. Recommended to use 100×100 mm reinforcing mesh.
  5. Heating cable OHC30.
  6. Concrete or cement-sand mortar where heating cable is laid. Min. 50mm.
  7. Surface layer (asphalt, paving stone, e.t.c.).

*OHC30 Heating cable also can be laid into sand.

 

Recommended Heating Power

Type of area
min. power, W/m²
max. power, W/m²
Stairs
300
400
Sidewalks
300
400
Walk ramps
300
400
Loading ramps
350
500
Bridges
350
500
Paved terraces
300
400
Balconies
300
400
Soft roof
250
300
Hard roof
300
350
Gutters
160
250
Downspouts
60
130