Loose Heating Cable - Grand Meyer® THC20

Twin-core resistive type electric loose heating cable Grand Meyer THC20 with a linear output of 20 W/m. Used for underfloor heating systems as main heating or as comfort underfloor heating. Also can be used for protection against snow and ice of the small open areas. It is delivered in the form of ready-made heating sections with an installation connecting wire and sealed connecting and end sleeves.

SPECIFICATIONS OF THE HEATING CABLE
Cable type
twin-core screened
Power supply
~230V
Linear power at rated voltage
20 W/m
Maximum operating temperature
+90⁰С
Minimum installation temperature
-10⁰С
Minimum bend radius
6 cm
Cable outer diameter
5.0 mm
Installation wire feeding the heating cable
3.0m, PVC 3x1.0mm²
Color of connected wires
brown - phase (L), blue - zero (N), yellow-green - "ground" (PE)
Length tolerances
±2%

Heating cable design

  1. Stranded heating conductors made of CuNi, CuCr, NiCr alloys depending on the resistance.
  2. Internal insulation made of heat-resistant cross-linked polyethylene of the new generation XPLE.
  3. Aluminum foil screen.
  4. Drain conductor made of stranded Al-Mg wires.
  5. External insulation made of PVC-modified polyvinyl chloride with increased heat resistance.

Technical characteristics of Loose Heating Cable Grand Meyer THC20

Cable article
HEATING PART LENGTH, M
POWER, W
CURRENT, A
RESISTANCE, OhM
THC20-10
10
200
0,9
251 ... 291
THC20-15
15
300
1,4
168 ... 194
THC20-23
23
460
2,1
109 ... 127
THC20-32
32
640
2,9
79 ... 91
THC20-45
45
900
4,1
56 ... 65
THC20-57
57
1 140
5,2
44 ... 51
THC20-70
70
1 400
6,4
36 ... 42
THC20-85
85
1 700
7,7
29 ... 34
THC20-98
98
1 960
8,9
25 ... 30
THC20-115
115
2 300
10,5
21 ... 25
THC20-160
160
3 200
14,5
15 ... 19

Contents of delivery

  • Loose Heating Cable Grand Meyer THC20
  • Corrugated tube made of self-extinguishing PVC with plug for temperature sensor
  • System installation instructions
  • Warranty card

To control the operation of a warm floor, we recommend using
the Grand Meyer temperature controllers.

GM-109

GM-109

GM-119

GM-119

HW500

HW500

HW700

HW700

MST-1

MST-1

MST5

MST-5

W350

W350

THC20

Recommendations for the selection of Loose Heating Cable Grand Meyer THC20

Cable Article
LENGTH, M
POWER, W
MAX. HEATING AREA (M²) AT LAYING SPACING (POWER DENSITY, W/M²)
7,5 cm
267 W/m²
10 cm
200 W/m²
12,5 cm
160 W/m²
15 cm
133 W/m²
17.5 cm
114 W/m²
THC20-10
10
200
0,75
1,0
1,25
1,50
1,75
THC20-15
15
300
1,13
1,50
1,88
2,25
2,63
THC20-23
23
460
1,73
2,30
2,88
3,45
4,03
THC20-32
32
640
2,40
3,20
4,00
4,80
5,60
THC20-45
45
900
3,38
4,50
5,63
6,75
7,88
THC20-57
57
1 140
4,28
5,70
7,13
8,55
9,98
THC20-70
70
1 400
5,25
7,00
8,75
10,50
12,25
THC20-85
85
1 700
6,38
8,50
10,63
12,75
14,88
THC20-98
98
1 960
7,35
9,80
12,25
14,70
17,15
THC20-115
115
2 300
8,63
11,50
14,38
17,25
20,13
THC20-160
160
3 200
12,00
16,00
20,00
24,00
28,00

Installation of the Loose Heating Cable Grand Meyer THC20

  1. Concrete base (floor slab).
  2. Thermal insulation.
  3. Heating cable section THC20.
  4. Cement screed 3-5 cm high.
  5. Temperature sensor (installed in a corrugated tube, the end of which is plugged).
  6. Mounting tape.
  7. Floor covering (ceramic tiles, marble, laminate, linoleum, etc.).
  8. Temperature controller.